Name

MMCC-710 — H.323 destination missing

Severity

C (critical)

Message text

No H.323 Identifier in Setup packet

Description

A non-transparent session from client has arrived, matching ACL has no PLUG-TO configured. In this case, H.225 Setup packet must identify the real destination. However, Setup packet does not contain it.

Proxy cannot determine the destination, session terminates.

Check proxy configuration and if correct, please contact authors.

See also

transparency(7), access-control(7), logging(7)

Authors

This man page is a part of Kernun Firewall.
Copyright © 2000–2023 Trusted Network Solutions, a. s.